Artículo de revista
Evaluación de selladores de fosas y fisuras realizados con resina y con ionómeros vítreos
Evaluation of pit ans fissures sealants made with resin and with glass ionomer
Donna Fabre, María Gabriela
Universidad Nacional de Cuyo. Facultad de Odontología
- Enviar un email al autor
Fernandez, Alejandro Luis
Universidad Nacional de Cuyo. Facultad de Odontología
- Enviar un email al autor
Peña, José
Universidad Nacional de Cuyo. Facultad de Odontología
- Enviar un email al autor
Publicado en el 2014 en
Revista de la Facultad de Odontología,
Vol. 8, no. 1
Idioma:
Español
Resumen:
Español
En el presente trabajo se evaluaron 4 casos clínicos de pacientes con
riesgo de caries pero que poseían molares sin lesiones, a los cuales
se les colocó selladores de fosas y fisuras: en dos pacientes con resina
y en dos pacientes con ionómero de vidrio. Los mismos fueron
controlados en su permanencia en boca, los de resina en 6 meses y
los de ionómero en 2 años, no encontrándose diferencias clínicas
entre los materiales utilizados, debido a la diferencia en el tiempo de
control de los mismos.
Paralelamente, se realizó un trabajo in vitro con dos grupos de 10
molares cada uno, tratados el grupo 1 con sellador a base de resina
y el grupo 2 con sellador de ionómero de vidrio. Luego de someter
las muestras a la acción de un colorante (azul de metileno) se seccionaron
longitudinalmente y se observaron en una lupa estereoscópica
para ver si el colorante había penetrado o no por la interfase
sellador/esmalte. No se encontraron diferencias estadísticamente
significativas (a>0.05) entre los grupos analizados.
Inglés
In this paper, 4 clinical cases of patients with caries risk, who had
healthy molars, were evaluated. Pit and fissure sealants were placed
in two patients with resin and in two patients with glass ionomer.
They were monitored in mouth; the ones with resin for 6 months and
the ones witf ionomer for 2 years. Clinical differences between the
applied materials were not found due to the differences in the
monitorig time of them.
At the same time, an in vitro work was carried out with two grous
who bad 10 molars each. Group number 1 was treated with a sealer
based on resin and group number 2 was trated with a glass ionomer
sealer. Both groups, after the samples underwent a process with a
colouring (methylene blue), were sectioned lenghtwise and observed
with a stereoscopic magnifyng glass in order to see whether the
colouring had penetrated or not on the sealer/enamel interphase.
Statistically, no significant dyfferences (a> 0.05) between the
analyzed groups were found.
Disciplinas:
Palabras clave:
Descriptores:
Donna Fabre, María Gabriela; Fernandez, Alejandro Luis; Peña, José (2014) "Evaluación de selladores de fosas y fisuras realizados con resina y con ionómeros vítreos: ". En: Revista de la Facultad de Odontología, Vol. 8, no. 1, p. 10-15.
Dirección URL del artículo: https://bdigital.uncu.edu.ar/5996.
Fecha de consulta del artículo: 25/04/24.
Este obra está bajo una Licencia Creative Commons Atribución-NoComercial-CompartirIgual 3.0 Unported.
Conozca más sobre esta licencia >